macbethcal (1)
NAME
|
macbethcal - compute color compensation based on measured Macbeth chart |
SYNOPSIS
|
macbethcal [ -d debug.pic ][ -p xul yul xur
yur xll yll xlr ylr ] scannedin.pic [
calibout.cal ]
macbethcal -c [ -d debug.pic ] [
measured.xyY [ calibout.cal ] ] |
DESCRIPTION
|
Macbethcal takes a scanned image or measurement set
of a Macbeth ColorChecker TM
color rendition chart and computes a color mapping function
suitable as input to pcomb(1). |
|
In the first form, macbethcal takes a scanned image
of a Macbeth chart that has been converted into a Radiance
picture using a fixed procedure. When used properly as input
to pcomb, the computed calibration file will adjust
the brightness and color of any similarly scanned and
converted image so as to best match the original. If the
lighting conditions are carefully controlled (as in the case
of a flatbed scanner), it is even possible to get reliable
reflectance values this way, at least within 10% or so. The
input picture is named on the command line. The output
calibration file will be written to the standard output if
no file name is given on the command line. |
|
In the second form, the input is from a file containing
measured values for each Macbeth color. This file must
contain entries of the form: |
|
N x y Y
Where N is the number of the corresponding Macbeth color. (See back of ColorChecker chart for color names and indexing, but it basically starts from the upper left with 1 and proceeds in English text order to the lower right, which is 24.) The values x, y and Y are the 1931 CIE (x,y) chromaticity coordinates followed by the luminance for that color, which can be in any units. If a white value is known (i.e. maximum output level), then it may be given as entry number 0. The entries may be in any order, and comments may be included delimited by a pound sign ('#') and continuing to the end of line. It is recommended that measurements be done for all 24 colors, but the only required entries are the 6 neutral values on the bottom row of the chart. |
|
Computing a mapping from measured colors is usually more
convenient when calibrating a particular output device. This
is accomplished by printing the picture
macbeth_spec.pic (which may be found in the standard
RADIANCE library directory in the lib subdirectory) and
measuring the output with a chroma meter or
spectrophotometer. |
|
For a scanned image, the locations of the 24 Macbeth patches
in the input picture must be known. If the chart borders are
not at the edges of the input picture, or the chart has been
reversed or rotated or is uncentered or at an oblique angle,
then it is necessary to specify the pixel locations of the
corners of the chart with the -p option. The corner
postions (x,y pixel addresses as given by the
ximage(1) "p" command) are ordered on the
command line: upper-left, upper-right, lower-left,
lower-right (i.e. English text ordering). These coordinates
should be the outside corner positions of the following
patches: |
|
upper-left = 1. dark skin
upper-right = 6. bluish green
lower-left = 19. white
lower-right = 24. black
If the chart has been flipped or rotated, simply give the pixel positions of the appropriate patch corners, wherever they are in the image. (Note: if the Radiance picture has been flipped or rotated with pflip(1) or protate(1), ximage will report the original pixel positions if the -c option was not used by the reorienting program(s). This will be wrong, so be sure to use the -c option.) Macbethcal can handle a chart with any orientation or perspective warping if the corner coordinates are given correctly. The debug picture output is the best way to check for consistency. (See the -d option, below.) |
|
The -d option may be used to specify an additional
output file, which will be a picture comparing the scanned
image processed according to the computed mapping against
the standard Macbeth colors. It is a good idea to use the
debug option to check that the color patches are being
located correctly, and to see how well macbethcal
does at matching colors. The center of each patch will show
the target color; the left side of each patch will show the
original color, and the right side will show the corrected
value. If the match works well, the debug picture should
have a sort of "notch on the left" look in each
patch. Macbeth colors that could not be matched because they
were out of gamut on this device are indicated with diagonal
lines drawn through the associated target
colors. |
METHOD
|
Macbethcal computes the color mapping in two stages.
The first stage uses the six neutral color patches at the
bottom of the Macbeth chart to compute a piecewise linear
approximation to the brightness mapping of each RGB primary.
The second stage looks at all the colors that are within the
device's gamut to compute a least-sqaures fit for a linear
color transformation from the measured space into the
standard Radiance RGB space (as defined by the three
primaries in src/common/color.h). |
|
Thanks to the nature of inverse mappings, this method should
work either for converting scanned data to match the
original, or for preconditioning pictures to be sent to
specific output devices. In other words, the same
calibration file works either for correcting scanned images
OR precorrecting images before printing. |
|
A warning is printed if some unsaturated colors are
determined to be out of gamut, as this may indicate a poor
rendition or improper picture alignment. The debug picture
will show which colors were excluded by drawing diagonal
lines through their entries. |
NOTE
|
It is very important that the same settings be applied when
scanning or printing other images to be calibrated with the
computed file. In particular, all exposure adjustments
should be fixed manually, and no tweaking of the settings
should be done along the way. The final result will be best
if the original scanned image is not too far off from what
it should be. In the case of slide and negative scanners, it
is best to apply the recommended calibration file for the
type of film used, so long as this calibration is fixed and
not adjusted on a per-image basis. |
CHART AVAILABILITY
|
The Macbeth chart is available at most photographic supply
stores, or may be ordered directly from
Macbeth: |
|
Macbeth
Munsell Color
405 Little Britain Rd.
New Windsor, NY 12553-6148
tel. 1-800-622-2384 (USA)
fax. 1-914-561-0267
The chart sells for under $50 US at the time of this writing. |
EXAMPLES
|
To compute a calibration for a FunkyThing scanner and check
the results: |
|
ra_tiff -r mbscan.tif mbscan.pic
macbethcal -d debug.pic mbscan.pic FunkyThing.cal
ximage debug.pic |
|
To apply this computed calibration to another scanned
image: |
|
ra_tiff -r another.tif | pcomb -f FunkyThing.cal - >
another_calib.pic |
|
To compute a calibration file for the BigWhiz film recorder,
after taking measurements of a slide made from
macbeth_spec.pic: |
|
macbethcal -c macbeth_spec.xyY BigWhiz.cal |
|
To prepare a picture prior to output on the same film
recorder: |
|
pcomb -f BigWhiz.cal standard.pic >
toprint.pic |
|
To use pcond(1) to also adjust the image for human
response: |
|
pcond -f BigWhiz.cal -h standard.pic >
toprint.pic |
AUTHOR
|
Greg Ward
Paul Heckbert supplied code for perspective projective
mapping |
SEE ALSO
|